No Sales Tax!
 
EQUIPMENTLAND.com
Contact equipmentland.com
 
   attachments, implements and tools for construction, farm and home
 
  

scart
qcart
specials
warranty
policies
contact
parts

   

FEMA Member
Locator Dept.

Home > Heaters > Indirect Fired Heaters > 400-46 Diesel Heaters

400K BTU Gasoline Heaters

400K Diesel Heater 400K BTU Self Contained Indirect Fired Oil Heater - HERM-BT400-46YAN
- 400K BTU
- 1500 CFM
- Diesel Yanmar Engine
- 716 lbs.
add to card unavailable

400K Diesel Heater 400K BTU Self Contained Indirect Fired Oil Heater - HERM-BT400-46AT
- 400K BTU
- 1500 CFM
- Diesel Aerotech Engine
- 716 lbs.
add to card unavailable

400k BTU Gasoline Heater plane hangar       Gasoline Heater Front       Gasoline Heater Side      Gasoline Heater Cut Away
Click for larger images

400k BTU Heater

- Entirely self sustained heater uses a diesel engine powered package
- Full diesel configuration uses a 6.5HP air cooled diesel engine, with electric starting and is proven in temperatures to -62° C ( -80° F ). The BT 400-46 series H-1 heater illustrated is currently the State of the Art heater with the United States Air Force.

RUNNING GEAR (Common to all our 400 Series diesel heaters)
- 2-wheel flat-bed trailer
- 12 gauge C channel construction, completely surrounding and protecting the fuel cell
- Tire size 6.90-9
- Two hand brakes
- Adjustable tow bar serves as support when trailer is at rest
- Unit is towable at speeds up to 32kph (20mph) non-highway use on concrete or asphalt surfaces

- Diesel engine driven that can run on diesel, kerosene or jet burning fuel
- Heat Output: 400,000 BTU/hr
- Operates at temperatures as low as -64 degrees F (-54 C)
- Hinged cabinet opens to create access to the engine.

- Height: 44"
- Length: 68.5"
- Width: 57.5"
- Dry Weight: 325 kg (716 lbs.)
- Ventilating Air Output: 5000 lbs./hr at -65 degrees F (-54 C)
- Maximum Temperature Rise: 350 degrees F (177 C) at -65 degrees F (-54 C)
- Type Temperature Control: hand selected 150-280 degrees F (65-138 C), 350 degrees F (177 C) overheat cutout point
- Fuel Consumption: 3.6 gal/hr at -65 F ambient, 2.5 gal/fr at 0 F ambient
- Maximum Heating Capacity: 400,000 BTU/hr at -65 F at sea level
- Operating Ambient Range: -65 to 120 degrees F
- Outlet Air Temperature Range: 180-280 degrees F (adjustable)
- Rated Airflow: 1500 SCFM at 0 degrees in W.G.
- Type of Fuel: All Diesel and Kerosene plus JP-4, JP-5, JP-8, DFA, DF-1, DF-2
- Fuel Capacity: 35 gallons, self contained tank
- Engine:
- a) Honda 7 hp electric start key ignition (recommended)
- b) Lister Petter 7 hp diesel engine (Military orders)
- c) Kubota 6.7 hp Electric start
- One Piece Exhaust Pipe: 5" diameter X 36" long
- Flexible Duct Sizes: 12" diameter X 15' long (1 each)
- Low Temperature Starting Requirements: Engine will start and operate after five minutes preheating at temperatures as low as -65 degrees F (-65) F
- Finish: Normally yellow, custom colour selections available